Our Technology

 

Capenergy has developed the most powerful equipment and technology on the market. Unique with the possibility of automatic treatments and multipatology. Accelerates and stimulates the natural processes of cellular repair achieving a speedy recovery, both in sports medicine, physiotherapy, dentistry, uro-gynecology, chiropody and aesthetic medicine. The best is that we brought this amazing European technology to all our great clients in the South of Florida.

 

LOSE UP TO 2 SIZES IN 1 SESSION!

 
 
 

Tecartherapy C400

Capenergy models are designed to provide enough energy output to generate an optimal biological effect, while maintaining the safety conditions.

All devices are equipped with an overload alarm, which protects the equipment andthe patient before any excessive of energy. Capenergy machines have a safety circuitthat allows patients to monitor therapy.

Technical Characteristics

  • Frequency: 0.8MHz, 1 MHz, 1.2MHz

  • CAPACITIVE:

Automatic Capacitive Plates Outlets: 4 (3 if you use the manual output of channel 3)
Manual Capacitive Outlets: 4 (3 if you use the manual output of channel 3)
Passive Plates Outlets: 4

  • RESISTIVE:

Manual Resistive Outlets: 1 (none if you use the automatic outputs of channels 1,2, 3 &4) 

  • Voltage and output power:

  • Automatic & Manual Modules 40 / 1000

  • V rms (aprox.) 320 – 380

  • Watt rms (aprox.) 130 – 75

  • Voltage: 230Va.c. +/- 10%

  • Maximum input power: 1240 W

  • Weight: 22,5 Kg. With stand 42,3 Kg

  • Dimensions: 556 x 420 x 220 mm

  • Ambient operating temperature: 0 – 40° C

  • Maximum temperature for storage and transport: 0 + 70° C

  • Maximum storage and transport humidity: 25 + 85%

  • Automatic plate surface: aprox. 240 cm2

  • Capacitive electrodes: Ø 33 mm – Ø 53 mm – Ø 65 mm

  • Resistive electrodes: Ø 33 mm – Ø 53 mm – Ø 65 mm

  • Classification for electrical safety: Class 1

  • Frequency Selection: Yes. In need of therapy: 0.8 MHz. 1 MHz. 1.2MHz.

  • Tuning Frequency in Different Therapeutic Areas from the same patient: Yes. The operator can select the frequency of interest in each of the channels (1 MHz 0.8 MHz 1.2 MHz).

  • Number of Channels Available: 4 (Equivalent to treat four areas of the patient´s body simultaneously)

  • Intelligent Channel: Yes. The same channel allows you to use the manual capacitive and resistive handprobe, and the capacitive automatic plate.

  • Multichannel Technology: Sí.

    Application of the capacitive electrode in the four channels: Yes.
Application of the resistive electrode in the four channels: Yes.
Application of the automatic plate in the four channels: Yes.

  • Automatic Technology: Yes.

  • Option of Crossfires (manual CAP-RES combined application): Yes.

  • Option of Combined Manual & Automatic Treatments: Yes.

  • Option of Bilateral Lymphatic Drainage –unattended–: Yes.

  • Temperature Monitoring by Sensor: Yes. In automated plates only.

  • Suggestions of Treatment by Guided Program: Yes. (Athermal. Thermal. Highly thermal).

  • Basic or Advanced Screen: Yes.

  • Viewing Biofeedback Parameters (absorbed energy , qualitative indication of real-time power, coupling, temperature, etc.), to conduct clinical research: Yes.

  • Safety Switch: Yes.

  • Hygiene Systems for Accessories: Yes. Protective membranes for manual capacitive handpieces, and pouches (with or without gel) for automatic capacitive accessories.

Explanation on the different uses with the devices

Application on an area of the body at once:

  • Capacitive Manual Treatment

  • Resistive Manual Treatment

  • Automatic Capacitive Treatment

TECHNOLOGY NEWS & PRESS